15231700281
The CLT/A type cyclone dust collector is an improved version of the XLT cyclone dust collector. Its structural feature is a downward sloping spiral tangent gas, and the top plate is a spiral shaped guide plate. The larger the angle of the guide plate, the smaller the pressure loss, but the dust removal efficiency decreases. In general, the angle of the guide plate is 8 ° -20 °, and the CLT/A cyclone dust collector uses 15 °. Due to the tangential entry of gas and the role of a guiding plate, it can enter the small vortex airflow formed by the gas's movement, reducing kinetic energy consumption and improving efficiency. Another characteristic of it is that the cylinder is slender and the cone is long, and the cone angle is small, which can improve efficiency, but the pressure loss is also high.
The CLT/A type cyclone dust collector is mainly composed of a cyclone cylinder, an ash collection hopper, and a volute (or air collection cap). According to the number of cylinders, there are five combinations: single cylinder, double cylinder, triple cylinder, quadruple cylinder, and triple cylinder. Each combination has two ways of air outlet: X-type (horizontal air outlet) is generally used for negative pressure operation; Y-shaped (upper air outlet) is generally used for positive or negative pressure operation.
The CLT/A type cyclone dust collector is based on the diameter of the cylinder, with a total of 11 specifications ranging from 300 to 800mm, with intervals of 50mm. According to the number of cylinders, there are five types: single cylinder, double cylinder, triple cylinder, quadruple cylinder, and triple cylinder. Each combination has two ways of air outlet, one is Type I (horizontal air outlet), which is generally used for negative pressure operation; One type is Type II (upper air outlet), used for positive or negative pressure operation. For Type I combinations, there are two types of double tube combinations: center inlet and outlet air and side inlet and outlet air; Single cylinder and triple cylinder only have one type of side intake and exhaust, while four cylinder and six cylinder combinations only have a central intake and exhaust type. For various combinations of Type II, any of the inlet positions in Type I can be used.
The cylinder and volute have two types: right-handed and left-handed. During installation, the intake and exhaust can be assembled in different directions with a 90 ° rotation. The single cylinder combination of the ash discharge device is equipped with a conical flash valve, while the other four combinations are equipped with a rotary feeder. The flange gasket is selected according to different working gas temperatures. Asbestos rubber gasket is used when the temperature is above 60 ℃, and rubber gasket is used when the temperature is below 60 ℃. After assembly, a pressure test of no less than 3000Pa should be conducted to ensure airtightness and no air leakage.
The CLT/A type cyclone dust collector is suitable for capturing dry non fiber dust containing high density and large particles in the gas. Commonly used in industries such as smelting, casting, building materials, sandblasting, refractory materials, etc.